Page view 49
Digital Video Recorder User Manual
44
4.8 P.T.Z configuration
P.T.Z configuration includes two submenus: serial port and advance
Serial port
Step1: enter into system configurationP.T.Z configurationserial port; refer to Fig 4-37
Step2: tick off Enable and setup the value of address, baud rate and protocol according to the settings of the speed dome.
Fig 4-37 P.T.Z configuration-serial port
Advance
Step1: enter into system configuration P.T.Z configurationadvance; refer to Fig 4-38:
Step2: in the Advance interface, after clicking preset Setting button, a dialog box will pop-up as Fig 4-39:
Parameter
Meaning
Address
The address of the PTZ device
Baud rate
Baud rate of the PTZ device. Range form: 110,
300, 600, 1200, 2400, 4800, 9600, 19200,
34800, 57600, 115200, 230400, 460800,
921600.
Protocol
Communication protocol of the PTZ device.
Range from: NULL, PELCOP, PELCOD, LILIN,
MINKING, NEON, STAR, VIDO, DSCP, VISCA,
SAMSUNG, RM110, HY, N-control.
Simulative
Cruise
If enabled, no matter whether the PTZ device
supports cruise or not, the presets will cruise.
Page view 49